Wallint Solar  

 

Wallint® solar is Klober's new reflective air barrier and vapour control layer. With a vapour resistance of over 500 MNs/g, it far exceeds the requirements set out in BS9250 (Code of Practice for design of the airtightness of ceilings in pitched roofs). Its reflective surface reduces heat loss through the roof. Moreover, when combined with other products in Klober's airtightness range, it will help to minimise energy loss.

  • Special features Vapour resistance of 250 MNsg. This low vapour resistance quality also allows damp timber to rapidly dry out. Reflective surface.
  • Suitability/use Suitable for inner face of walls (including timber frame), cold and warm roof applications. Also suitable for ceilings and walls of rooms in the roof, and on ceilings below non-habitable lofts.
  • Material(s) Composite woven, non-woven, foil
  • Resistance to water penetration EN 1928 W1
  • Tensile strength (Longitudinal/ transverse EN 12311-2) 600N/50m, 550N/50mm
  • Tear strength/resistance (Nail shank) longitudinal / transverse EN 12310-1: 250N, 300N
  • Resistance to heat (EN12101-2) -40ºC /+80ºC
  • Water vapour transmission >500 MNsg
  • Resistance to air penetration 0,003m3/m2 h 50 Pa
  • Fire resistance Class (EN 13501-1) E